Signatures: The Issuer and Receiver complete and sign the front of the permit (Section 4) once the Hazard Analysis has been completed and all specified hazard controls are in place, required gas tests recorded, and supplemental forms attached. Additional signatures are required for extended permits or when gas tests are at levels indicated in the Gas Test Information Table.
Countersignatures: The Issuer must obtain the approval and signature of other organizations whose operations will be affected by the work.
Renewed Permit: Requires signatures of the Issuer and Receiver coming on shift, and notification to all countersigning organizations.
Extended Permit: Requires signatures of the Division Head (or above) of both the issuing and receiving organizations.